Power and heating residue station Linz plc Linz (AT)
Operator
Municipal energy supplier.
Fuel
Industrial and municipal residues, severage sludge.
Features
bubbling fluidized bed combustion system with tailend boiler.
Extent of order
Lot 1: Waste incineration plant with bubbling fluidized bed technology Linz for combined heat and power production - personal reference of Dr. Steer
Technical data
Thermal firing capacity | 66 MW |
Steam production | 82 t/h |
Fuels | Sludge, screening, residues |
Lower heating value (min. - max.) | 7,0 - 18,0 MJ/kg |
Steam temperature | 435 °C |
Design pressure | 40 bar |
Year of commissioning | 2011 |